(+65) 62597114      enquiry@keysolutionsgroup.com.sg

Rotronic

Rotronic

Rotronic

ROTRONIC offers a comprehensive line of reliable hygrometers to precisely measure relative humidity, dew point, water activity, temperature and other psychrometric parameters. Applications range from cleanrooms, semiconductor, pharmaceutical, commercial HVAC and building management systems, to weather stations, test and research laboratories, industrial process measurement / control, and product quality control.

Problem-free, accurate humidity measurement results from the most stable sensor in the industry combined with the unique HygroClip ® digital probe technology, designed to practically eliminate any maintenance downtime. The instruments and probes are designed to comply with the electronic records and electronic signatures (ERES) regulations from both FDA and GAMP.

Transmitters

  • HF3 – Commercial HVAC

 

 

 

 

 

 

 

  • HF7 – Industrial Control

 

 

 

 

Portable Indicators

  • Hygropalm 21

 

 

 

 

  • Hygropalm 23

 

Data Loggers

  • HL 20/21 – Compact Humidity Temperature Data Logger

 

 

 

 

 

 

 

  • LOG-PT1000-RC-US / LOG-PT1000-30RC-US

 

 

 

 

 

 

 

Probes

Product Catalogue
HF3 - Commercial HVAC

The HF3 transmitter is designed for fixed installation in cost sensitive commercial HVAC applications where conditions are within the range of 0 to 100 %RH and -40 to 60°C (-40 to 140°F). The HF3 will satisfy application requirements ranging from the most basic to demanding.

The HF3 transmitter is available in different configurations and has an extensive set of settings and functions that can be configured and enabled with the ROTRONIC HW4 software after connecting the HF3 to a PC.

×

Product Catalogue
HF4 - Precision HVAC

The HF4 transmitter is designed for fixed installation in HVAC and light industrial applications that require precise measurement of humidity and temperature within the range of 0 to 100 %RH and -50 to 100°C (-58 to 212°F).

The HF4 transmitter is available in different configurations and has an extensive set of settings and functions that can be configured and enabled with the ROTRONIC HW4 software after connecting the HF4 to a PC.

×

Product Catalogue
HF5 - Industrial Control

The HF5 transmitter is designed for fixed installation in HVAC and industrial applications, and provides two analog outputs or a digital output signal corresponding to relative humidity, temperature, dew point or another psychrometric parameter. The HF5 uses a plug-in HygroClip 2 probe, the model of probe being determined by the application. The measuring range is within 0 to 100 %RH and -100 to 200°C (-148 to 392°F), depending on the probe. All HygroClip 2 probes feature durable sensors, consistent performance and can be hot-swapped at any time to facilitate routine calibrations.

The HF5 transmitter is available in different configurations and has an extensive set of settings and functions that can be configured and enabled with the ROTRONIC HW4 software after connecting the HF5 to a PC.

×

Product Catalogue
HF7 - Industrial Control

The HF7 transmitter series is designed for fixed installation in industrial applications where conditions are within the range of 0 to 100 %RH and -100 to 150°C (-148 to 302°F). The probe of the HF7 can survive exposure to temperature up to 200°C (392°F). Equipped with a metal enclosure and a metal probe, the HF7 can handle the toughest industrial environments.

The HF7 transmitter is available in different configurations and has an extensive set of settings and functions that can be configured and enabled with the ROTRONIC HW4 software after connecting the HF7 to a PC.

×

Product Catalogue
HF8 - Industrial Control

The HF8 is a multi-function transmitter designed to meet with a single self contained unit the requirements of applications that had previously necessitated more than one instrument. The HF8 has an extensive set of optional functions and settings that can be configured and enabled with the ROTRONIC HW4 software after connecting the HF8 to a PC.

×

Product Catalogue
Hygropalm 21

The HP21 is a highly accurate hand-held indicator that displays relative humidity, temperature and the dew or frost point. The HP21 is perfect for spot checking HVAC installations, manufacturing and storage areas, and generally for all ambient air measurement within the temperature range of -10 to 60°C (14 to 140 °F). The key features of the HP21 will meet user requirements ranging from the most basic to demanding.

The HP21 indicator has an extensive set of settings and functions that can be configured and enabled by the user with the ROTRONIC HW4 software. In spite of its sophistication, the HP21 can still be used just as a simple humidity and temperature indicator. Whether you decide or not to take advantage of its full potential, the HP21 will let you have it your way.

×

Product Catalogue
Hygropalm 22

The HP22 is a versatile hand-held indicator that displays relative humidity, temperature and a calculated parameter such as the dew or frost point, based on the measurements of a HygroClip 2 plug-in probe.

Probe selection is based on the application. Depending on the HygroClip 2 probe model, the measuring range is within 0 to 100 %RH and -100 to 200°C (-148 to 392°F). The HygroClip 2 probes feature durable sensors and consistent performance. All HygroClip 2 probes can be hot-swapped to facilitate routine calibrations.

The HP22 indicator has an extensive set of settings and functions that can be enabled and configured by the user either directly from the keypad or with the ROTRONIC HW4 software.

×

Product Catalogue
Hygropalm 23

The HP23 is a multi-function hand-held indicator that can read the data from up to two HygroClip 2 probes and display relative humidity, temperature and a calculated parameter such as the dew or frost point. Any probe input can also be configured by the user to accept a third party analog probe (restrictions apply).

Probe selection is based on the application. Depending on the HygroClip 2 probe model, the measuring range is within 0 to 100 %RH and -100 to 200°C (-148 to 392°F). The HygroClip 2 probes feature durable sensors, consistent performance and can be hot-swapped to facilitate routine maintenance.

The HP23 indicator has an extensive set of settings and functions that can be enabled and configured by the user either directly from the keypad or with the ROTRONIC HW4 software.

×

Product Catalogue
HL 20/21 - Compact Humidity Temperature Data Logger

The HL20 and HL21 are accurate humidity temperature data loggers designed for recording ambient conditions in indoor areas such as research laboratories, high-tech manufacturing facilities and warehouses, storage areas and containers for sensitive goods, museums, office buildings, etc.

×

Product Catalogue
HYGROLOG HL-NT - Advanced Humidity Temperature Data Logger

The HygroLog HL-NT humidity, dew point and temperature data logger can be used with any of the HygroClip 2 probes. The HL-NT can monitor up to 7 probes as well as up to two external on/off contacts, such a a door contact.

When used together with the validated ROTRONIC HW4 software the HygroLog HL-NT data logger complies with FDA 21 CFR part 11 regarding electronic data records and electronic signatures (ERES).

The HW4 software can display the data from several data loggers on multiple PCs and can centrally record on one of the PCs the measurement data from several loggers. As a protection against power outages and network failures, HW4 can be used to automatically download the locally recorded data at regular intervals of time.

×

Product Catalogue
LOG-HC2-RC-US Wireless Data Logger

  • Records relative humidity and temperature data
  • Temperature application range: –40 to + 85 °C
  • HygroClip 2 probe accuracy: ±0.8 %RH and ±0.1°C
  • Interchangeable digital probe (any HygroClip 2 probe model)
  • Radio frequency: 915 MHz (US standard) for optimum penetration through walls
  • High storage capacity: up to 250,000 Humidity & Temperature values with time, date and serial number
  • Long-term recording up to 6 years without battery replacement
  • Non volatile memory
  • Transmission distance: up to 100 m / 110 yd (free field)
  • USB or LAN wireless adapter
  • Data security: PIN (for activation and data access)
  • Plastic housing, white, IP65

×

Product Catalogue
LOG-PT1000-RC-US / LOG-PT1000-30RC-US

  • Records temperature data
  • Temperature application range: –40 to + 85 °C
  • Radio frequency: 915 MHz (US standard) for optimum penetration through walls
  • High storage capacity: up to 500,000 measured values with time, date and serial number
  • Long-term recording up to 6 years without battery replacement
  • Non volatile memory
  • Transmission distance LOG-PT1000-RC-US: up to 100 m / 110 yd (free field)
  • Transmission distance LOG-PT1000-30RC-US: up to 300 m / 328 yd (free field)
  • USB or LAN wireless adapter
  • Data security: PIN (for activation and data access)
  • Plastic housing, white, IP65

×

Product Catalogue
LAN-INTERFACE-US

Using an existing Ethernet infrastructure, multiple LAN wireless adapters can serve as an interface between the wireless data loggers and the PC.

  • Manage up to 100 digital wireless data loggers per adapter (915 MHz)
  • Network connection: 100 MBit Ethernet LAN (RJ-45)
  • Communication: via TCP/IP protocol
  • Wireless: connection of external SMA antenna possible
  • Configurable via web browser
  • Housing material: aluminum
  • Power supply: AC mains adapter

×

Product Catalogue
LOG-DS-EXT-US

The USB wireless adapter serves as an interface between the wireless data loggers and the PC (limited to one adapter per PC).

  • Manage up to 100 digital wireless data loggers (915 MHz)
  • Wireless: connection of external SMA antenna possible
  • Plug & Play

×

HC2-S: Ambient Air Probe for Indicator, Transmitter or Data Logger

  • Relative humidity, temperature measurement and dew point calculation
  • Outstanding accuracy and repeatability
  • Excellent long-term stability <1 %RH / year
  • Integrated data acquisition and calibration history
  • Auto-diagnostics with error compensation
  • Programmable alarm functions
  • Advanced easy-to-use calibration features
  • 100% field interchangeable

×

HC2-C04: Measurement in Tight Spaces

  • Humidity measuring range: 0..100 %RH
  • Temperature measuring range:-40…85 °C (-40…185 °F)
  • Probe tip diameter probe: 4 mm (0.16”)
  • Cable length electronics – probe tip: about 2 m (6.5 ft)
  • Electronics barrel: polycarbonate, black
  • Weight: approx. 150 g (5.3 oz)

×

HC2-C05: Measurement in Tight Spaces

  • Same as HC2-C04 but with 5 mm diameter (0.2”)
  • Can be equipped with Teflon dust filter SP-T05
  • Weight: approx. 160 g (5.6 oz)

×

HC2-IC1 / HC2-IC3:Through Wall Installation for Industrial Processes

  • Humidity measuring range: 0..100 %RH
  • Temperature limits at sensor:-100…200 °C (-148…392 °F)
  • Barrel – PPS black:IC1: diameter: 15 mm (0.6”) / Length: 100 mm (3.9”), IC3: diameter: 15 mm (0.6”)/ length: 250 mm (9.8”)
  • Probe cable length:IC102 / IC302: 2 m (6.5 ft) / IC105 / IC305: 5 m (16.4 ft)
  • Filter base (NSP-ME) with filter cartridge(specify when ordering)
  • Weight with 2 m cable: IC1: approx. 230 g (8.1 oz)+ 80 g (2.8 oz) per additional meter, IC3: approx. 260 g (9.2 oz)+ 80 g (2.8 oz) per additional meter

×

HC2-IE3: Fixed Installation in Pressurized Conduits and Vessels

  • Humidity measuring range: 0..100 %RH
  • Temperature limits at sensor:-100…200 °C (-148…392 °F)
  • Barrel – Stainless steel
  • NPT ½” thread for maximum 400 bar / 5800 PSI
  • Probe cable length: IE302: 2 m (6.5 ft), IE305: 5 m (16.4 ft)
  • Filter base (SP-MSB15)with filter cartridge (specify when ordering)
  • Weight with 2 m cable: approx. 290 g (10.2 oz) + 80 g (2.8 oz) per additional meter

×

HC2-IM1 / HC2-IM3 / HC2-IM4 / HC2-IM5:Through Wall Installations

  • Humidity measuring range: 0..100 %RH
  • Temperature limits at sensor:-100…200 °C (-148…392 °F)
  • Barrel – Stainless steel:15mm diameter. IM1:length: 120 mm (4.7”), IM3:length: 280 mm (11.0”). IM4:length: 430 mm (16.9”), IM5:length: 580 mm (22.8”)
  • Probe cable length: IM102 / IM302 / IM402 / IM502:2 m (6.5 ft)
    IM105 / IM305 / IM405 / IM505: 5 m (16.4 ft)
  • Filter base (SP-MSB15)with filter cartridge (specify when ordering)
  • Weight: approx. 260 g (9.2 oz) to approx. 680 g (24.0 oz) depending on model

×

HC2-P05: Hand-Held Probe for Measuring In Air Ducts

  • Humidity measuring range: 0..100 %RH
  • Temperature limits: -40…85 °C (-40…185 °F)
  • Probe tip: diameter: 5 mm (0.2”),length: 200 mm (7.9”)
  • Probe cable length: 2 m (6.5 ft)
  • Handgrip: POM, black -, barrel: PPS, black

×

HC2-HK25 / HC2-HK40: Hand-Held Air Probe With Wide Temperature Range

  • Humidity measuring range: 0..100 %RH
  • Temperature limits at sensor: HK25: -100…150 °C (-148…302 °F), HK40: -100…200 °C (-148…392 °F)
  • Barrel: HK25: dia.: 15 mm (0.6”) length: 250 mm (9.8”), HK40: dia.: 15 mm (0.6”)length: 400 mm (15.7”)
  • Probe cable length: 2 m (6.5 ft)
  • Handgrip: POM, black -, barrel: PPS, black
  • Filter base (NSP-ME) with wire mesh filter cartridge (SP-M15)
  • Weight:HK25: approx. 210 g (7.4 oz)HK40: approx. 240 g (8.5 oz)

×

HC2-HP28 / HC2-HP50: Hand-Held Probe for Measuring Materials in Bulk

  • Humidity measuring range: 0..100 %RH
  • Temperature limits at sensor:-40…85 °C (-40…185 °F)
  • Barrel: HP28: dia.: 10 mm (0.4”)length: 280 mm (11.0”), HP50: dia.: 10 mm (0.4”)length: 500 mm (19.7”)
  • Probe cable length: 2 m (6.5 ft)
  • Handgrip: POM, black -, barrel: PPS, black
  • Filter base (NSP-ME) and sintered steel filter cartridge (SP-S15)
  • Weight:HP28: approx. 200 g (7.1 oz) / HP50: approx. 250 g (8.8 oz)

×

HC2-HS28 / HC2-HS42: Hand-Held Probe for Measuring Paper

  • Humidity measuring range: 0..100 %RH
  • Temperature limits at sensor: -40…85 °C (-40…185 °F)
  • Blade:thick.: 4 mm (0.16”). Width: 22 mm (0.87”), Length: 280 mm (11.0”) / HS42:420 mm (16.5”)
  • Probe cable length: 2 m (6.5 ft)
  • Handgrip: POM, black -, barrel: PPS, black
  • Filter base (NSP-ME) with wire mesh filter cartridge (SP-M15)
  • Weight:HS28: approx. 240 g (8.5 oz) / HS42: approx. 300 g (10.6 oz)

×